REV.-A 
Step 
4: 
Insert the test program 
ROM 
in the capsule.  Make sure 
that 
the 
ROM 
pins are proper-
ly inserted 
into 
the socket. 
Note: 
When 
neither 
ROM 
capsule is empty, the 
test 
program 
ROM 
may be inserted in 
either 
ROM 
socket; ROMB 
or 
ROMC. 
When 
one 
ROM 
is  already installed, in-
sert the 
test 
program 
ROM 
in the 
empty 
socket. 
Fig. 
5-4 
ROM 
Capsule 
Sockets 
Step 5:  Replacethe 
ROM 
capsule cover. 
5.2.3 
Loading 
the 
Test 
Program 
Set the POWER 
switch 
ON 
and check 
to 
see 
that 
the menu 
shown 
in Fig. 
5-5 
appears on the 
LCD 
panel.  The display varies depending on the inserted 
ROM. 
If 
nothing 
appears on the panel, press 
the 
RESET 
switch. 
C::.;; 
r: 
1L..J.:\[j·-
,'·',"',;" 
•• 
1 
~ 
... 
I 
.• 
H  i 
Fig. 
5-5 
Tet 
Program 
Menu 
,--·;"',ivi 
'-_.· 
.... 
'·l 
•  Move the cursor so 
that 
"MAPTST' 
blinks, and then press the 
RETURN 
key. 
CU~'1 
CD~'! 
Note: 
One 
of 
the messages 
shown 
in Fig. 
5-6 
will 
be displayed, depending on the 
ROM 
capsule 
socket in 
which 
the program 
ROM 
is inserted. 
1. 
Message  displayed  when  test 
program 
ROM 
is  inserted  in 
ROM 
1 socket. 
2.  Message  displayed  when  test 
program 
ROM 
is  inserted  in 
ROM 
2 socket. 
Fig. 
5-6 
Test 
Program 
ROM 
Location 
Information 
Messages 
5-4