switch
SW3
off
and measure VB+ voltage.
N
Set
switch
SW3
ON.
Readjust
VRF
voltage
with
VR2.
Set
switch
SW3
ON,
press INITIAL
RESET
switch, and then turn
POWER
switch
ON.
y
Replace MARPLE
board.
Replace keyboard unit.
5-18
Replace test program
ROM,
press
RESET
switch, and then re-
load test pregram.
N