EasyManua.ls Logo

Epson PX-8 - Page 73

Epson PX-8
349 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REV.-A
Observed
Shift
Clock
Wave
Forms
SCK:
Measured
at
1
D,
pin 4
Figures
2-45
through
2-47
show
the SCK sig-
nal
waveforms
which
should be observed dur-
ing a serial data transfer. Fig.
2-45
is
an
enlargement
of
the single negative
going
pulse
shown
in Fig.
2-47.
Fig.
2-46
further
en-
larges one pulse in Fig.
2-44.
The three pulses
shown
in fig.
2-46
are used
to
allow
the
7508
to
perform
the
following
opera-
tions, in order
from
left
to
right:
1) Fetch the
command
stored in
the
gate array
GAH40M
to
7508.
2) Select
the
tiPD7008
channel.
3)
Read
the
A-D
converted data
from
tiPD7001.
Note:
Fig.
2-46
and
2-47
are enlargements
of
the
signal
shown
in Fig.
2-45.
2-49
2V
5V
10mS
Fig.
2-45
SCK
Signal
Waveform
(Serial
Data
Trans
for)
Enlargement
2V
5V
200~S
Fig.
2-46
SCK
Waveform
Pulse
Enlarge-
ment
2
(Serial
Data
Transfer)
2V
Fig.
2-47
SCK
Signal
Waveforms
During
Serial
Data
Transfer