Disassembly/Reassembly Detailed Disassembly/Reassembly Procedure for each Part/Unit 27
SE Group Confidential (Related Staff Only)
PF Roller
When removing the PF Roller, follow the procedure below.
1. Remove the PF Grounding Spring.
2. Release the dowel of the Bush, 8 on the right side of the PF Roller, and rotate it upward and align it with the cutout of the frame.
3. Remove the E-ring, 7 and slide the Compression Spring, 4 to the right.
4. Release the dowel of the Bush, 8 on the left side of the PF Roller, and rotate it upward and align it with the cutout of the frame.
5. Pull out the PF Roller to the left side from the hole of the frame and remove it from the frame.
When attaching the PF Grounding Spring, engage the longer bent leg to the groove of the PF Roller, and engage the other leg to the cutout of the
frame to secure the spring.
PF Roller
Compression Spring, 4
E-ring, 7
Left
Step 3
PF Grounding Spring
PF Roller
Step 1
Groove
Cutout
PF Scale / PF Encoder Assy
After installing the PF Encoder Assy, confirm the PF Encoder does not touch the PF Scale.
Sheild Plate Assy Upper Main Board
When tightening the screw that secures the Shield Plate Assy
Upper Main Board, use a screwdriver with the shaft length of
150 mm or more and tighten the screw straight. Otherwise, you
have to screw it obliquely and can not tighten it correctly
because the grip of the driver hits the lower frame.
Tighten the screws in the order indicated in the figure above.
Rear
1
Shield Plate Assy Upper Main Board
Front
Screwdriver
150 mm or more
Lower Frame
2
3
C.B.S-TITE SCREW,3X6,F/ZN-3C (8 ± 1 kgf·cm)
Board Assy
After installing the Board Assy, confirm the gap shown above is
uniform. If not, the Shield Plate Assy Upper Main Board pushes up
the Paper Guide (under ASF Assy). In such a case, loosen the
screw (A) and adjust the Shield Plate Assy Upper Main Board
position until the gap become even, then tighten the screw (A).
Gap
Paper Guide (under ASF Assy)
Shield Plate Assy Upper Main Board
A