EPSON Stylus C110/C120/D120/WorkForce 30/EPSON Stylus OFFICE B30/T30/T33/ME OFFICE 70 Revision C
MAINTENANCE Overview 111
Confidential
Figure 6-5. Lubrication on PF Roller Grounding Spring
Figure 6-6. Lubrication on LD Roller Shaft
<Lubrication Point>
Contact area with the PF Roller.
<Lubrication Type>
G-71
<Lubrication Amount>
φ 1 mm x 4 mm
<Remarks>
Use an injector to apply G-71.
Lubrication must be performed
only after installing the PF
Roller Grounding Spring.
PF Roller Grounding Spring
PF Roller
<Lubrication Point>
Cam A and Cam B of the LD
Roller shaft
<Lubrication Type>
G-71
<Lubrication Amount>
φ 1 mm x around each cam
<Remarks>
Use an injector to apply G-71.
Rub off excess G-71 with a
cotton bud if necessary.
Cam A
Cam B