4.5.15 ASF Unit
Part/Unit that should be removed before removing ASF Unit
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/Front
Frame/Right Frame/CR Motor/CR Scale/Hopper/Main Frame Assy.
Removal Procedure
1. Release the PE Sensor cable from the notches (x6) of the Base Frame and pull out
the cable out of the hole (x1).
Figure 4-68. Releasing PE Sensor Cable
2. Remove the screws (x2) that secure the ASF Unit.
Figure 4-70. Removing ASF Unit (1)
3. Release the guide pins (x3) of the Base Frame and the shaft (x1) of the ASF Unit,
and then remove the ASF Unit.
Figure 4-71. Removing ASF Unit (2)
When performing the following steps, be cautious not to get
injured with the sharp metal edges of the Frame Support.
Figure 4-69. Sharp Edges of Frame Support
PE Sensor Connector Cable
Notch
Hole
1
2
3
4
5
6
7
C.B.P. 3x8, F/Zn-3C (6±1kgfcm)
ASF Unit
1
2
ASF Unit
Dowel
Shaft