EasyManua.ls Logo

Epson Stylus OFFICE B30 - ASF Unit

Epson Stylus OFFICE B30
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus C110/C120/D120/WorkForce 30/EPSON Stylus OFFICE B30/T30/T33/ME OFFICE 70 Revision C
DISASSEMBLY/ASSEMBLY Disassembling Printer Mechanism 91
Confidential
4.5.15 ASF Unit
Part/Unit that should be removed before removing ASF Unit
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/Front
Frame/Right Frame/CR Motor/CR Scale/Hopper/Main Frame Assy.
Removal Procedure
1. Release the PE Sensor cable from the notches (x6) of the Base Frame and pull out
the cable out of the hole (x1).
Figure 4-68. Releasing PE Sensor Cable
2. Remove the screws (x2) that secure the ASF Unit.
Figure 4-70. Removing ASF Unit (1)
3. Release the guide pins (x3) of the Base Frame and the shaft (x1) of the ASF Unit,
and then remove the ASF Unit.
Figure 4-71. Removing ASF Unit (2)
C A U T I O N
When performing the following steps, be cautious not to get
injured with the sharp metal edges of the Frame Support.
Figure 4-69. Sharp Edges of Frame Support
PE Sensor Connector Cable
Notch
Hole
1
2
3
4
5
6
7
Frame Support
C.B.P. 3x8, F/Zn-3C (6±1kgfcm)
ASF Unit
1
2
ASF Unit
Dowel
Shaft
Guide Pin and Positioning Hole

Table of Contents