4.5.13 CR Unit
Part/Unit that should be removed before removing CR Unit
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/Front
Frame/Right Frame/CR Motor/CR Scale/Hopper/Main Frame Assy./Printhead
Removal Procedure
1. Remove the screw (x1) that secures the CR Scale Holder, and remove it.
2. Move the CR Unit in the direction of the arrow to remove the unit.
Figure 4-63. Removing CR Unit (1)
3. Release the Timing Belt from the groove of the CR Unit.
Figure 4-64. Removing CR Unit (2)
CR Scale HolderCR Unit
C.B.S. 3x6, F/Zn-3C (8±1kgfcm)
The Ink Position Label is not included in the CR Unit. When
replacing the CR Unit, order the Ink Position Label separately
and attach the label as shown below
Figure 4-65. Attaching Ink Position Label
Timing Belt
Groove
CR Unit
Ink Position Label Carriage Cover
Attach the label here.
The chipped corner must
come to the upper left.