Alarm Lists
E-10
EN/LZT 790 0023/1 R16A
Alarm Description Port Number Alarm ID Source Severity
VBI ANC334 closed captions not
detected on input
Unable to find closed caption data
on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
1 010C400B VBI minor
VBI WSS not detected on input Unable to find WSS (ETSI or AFD)
data on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
1 010C400C VBI minor
VITC not detected on input Unable to find VITC data on any of
the configured lines. Please check
the video input. For more details on
the type of VBI, see the VBI status
page.
1 010C400D VBI minor
Selected Time code source not
detected
For the selected Time code source
no Time code was found. If in auto
mode no source was found on any
input. Make sure that the correct
source is configured.
1 010C400E VBI minor
ANC Bar not detected on input ANC Bar data extraction is on but no
ANC Bar data is present
1 010C400F VBI minor
OP-47 not detected on input OP-47 data extraction is on but no
OP-47 data is present
1 010C4010 VBI minor
Max ANC Data Rate Exceeded The maximum bit-rate of the generic
ANC data output is exceeded. A
lower input ANC data rate is
required.
1 010C4011 VBI warning
VPS not detected on input
Unable to find VPS data on any
of the configured lines. Please
check the video input. For more
details on the type of VBI, see
the VBI status page
1 010C4012 VBI minor
Video 1 Encode Invalid
Configuration
An invalid configuration has been
applied to Main Channel. Check
Video Standard and Profile
selection.
0 010C4018 VCM
Module
minor
Advanced Parameters Advanced Encode Parameters are in
use.
0 010C401C VCM
Module
warning
Reflex PCR Exchange Timeout PCR Exchange message not
received within timeout period
1 010C4020 VCM
Module
warning
Reflex SetRate Msg Timeout Set Rate message not received
within timeout period
1 010C4021 VCM
Module
warning
Reflex Apply-Time out of range Set Rate message received that is
too late to be applied, or is more
than 5 seconds early. The alarm is
cleared by the reception of a valid
Set Rate message, or Reflex being
disabled
1 010C4022 VCM
Module
warning