EN/LZT 790 0023/1 R16A
3-57
Changes in colour to highlight that changes have been made but not applied
Figure 3.32 Simplified View - Configuration Changes Requiring Apply Button
3.20.1.4.2.1 Output Properties Configuration
Each type of output has a different set of parameters that can be configured. When
the output is configured a new accordion panel is displayed containing these
parameters. Parameters that have dependencies are described below.
IP Output Parameters
Source Address - By default this does not need to be configured. The unit will
automatically determine the appropriate source address for the transport stream.
It is possible to force the source address to a user defined value only when the
unit is configured in ‘Transparent’ mode in this case ensure that the multicast
address has been configured first.
Row and Column - These parameters are related to FEC on the IP output,
which needs to be licensed in order to be configured. The encapsulation mode
of the IP output needs to be set to enable FEC for these fields to become active.
The encapsulation mode must be set using the Advanced View.
IP TS Rate - This is the transport stream bitrate of the IP output. It does not
include overheads needed for IP encapsulation. If this field cannot be edited the
output is a mirror and the bit rate is determined by the main output.
ASI Output Parameters
Note: As the only configurable parameter for an ASI output is the bit rate, this
shares the IP properties panel if both are configured.