-- 2 3 --
bh32d1e
”Live TIG--start” (only A33)
With “Live TIG start” the arc strikes when the tungsten electrode is brought into
contact with the workpiece and then lifted away from it.
6.7 Remote control unit
The remote control unit is connected to the remote control socket on the power
source.
7 MAINTENANCE
Regular maintenance is important for safe, reliable operation.
Only those persons who have appropriate electrical knowledge (authorized
personnel) may remove the safety plates to connect or carry out service,
maintenance or repair work on welding equipment.
CAUTION!
All guarantee undertakings from the supplier cease to apply if the customer himself
attempts any work in the product during the guarantee period in order to rectify any faults.
7.1 Inspection and cleaning
Power source
Check r egularly that the welding power source is not clogged with dirt.
How often and which cleaning methods apply depend on: the welding process, arc
times, placement, and the surrounding environment. It is normally sufficient to blow
down the power source with dry compressed air (reduced pressure) once a year.
Clogged or blocked air inlets and outlets otherwise result in overheating.
TIG torch
The TIG torch’s wear parts should be cleaned and replaced at regular intervals in
order to achieve trouble--free welding.
GB