3 TECHNICAL DATA
0463 715 001
- 9 -
© ESAB AB 2021
3 TECHNICAL DATA
Technical data
ES 150i PRO ES 200i PRO
Outlet voltage 240V±15%
1~ 50/60Hz
115V±15%
1~ 50/60Hz
240V±15%
1~ 50/60Hz
115V±15%
1~ 50/60Hz
Primary current
I
max
MMA
20A 29A 29 A 29A
I
max
LiftTIG
12.5A 24A 19A 24A
No-load power demand
when in energy saving
mode
50W 50W 50W 50W
Setting range
MMA 20-150A 20-110A 20-200A 20-110A
Lift TIG 10-150A 10-140A 10-200A 10-140A
Permissible load at MMA
25% duty cycle 150A/ 26V 110A / 24.4V 200A/ 28V 110A/ 24.4V
60% duty cycle 97A/ 23.9V 70A/ 22.8V 129A/ 25.2V 70A/ 22.8V
100%dutycycle 75A/ 23V 55A / 22.2V 100A/ 24V 55A/ 22.2V
Permissible load at Lift TIG
25% duty cycle 150A/ 16V 140A / 15.6V 200A/ 18V 140A/ 15.6V
60% duty cycle 97A/ 13.9V 90A / 13.6V 129A/ 15.2V 90A/13.6 V
100% duty cycle 75A/ 13V 70A / 12.8V 100A/ 14V 70A/12.8 V
Apparent powerI
2
at
maximum current
4.8kVA 3.3kVA 6.9kVA 3.3kVA
Active powerI
2
at maximum current
4.75kW 3.26kW 6.8kW 3.26kW
Power factor at maximum current
Lift TIG 0.99 0.99 0.99 0.99
MMA 0.99 0.99 0.99 0.99
Efficiency at maximum current
MMA 82% 82% 82% 82%
Lift TIG 82% 82% 82% 82%
Open-circuit voltage U
0
max
VRD deactivated 78VDC 78VDC 78VDC 78VDC
VRD <35 V activated <30V <30V <30V <30V
Operating temperature -10to +40°C
(+14to 104°F)
-10to +40°C
(+14to 104°F)
-10to +40°C
(+14to 104°F)
-10to +40°C
(+14to 104°F)
Transportation
temperature
-10to +40°C
(+14to 104°F)
-10to +40°C
(+14to 104°F)
-10to +40°C
(+14to 104°F)
-10to +40°C
(+14to 104°F)