Installaon Safety Instrucons
The unit must be installed by a suitably qualified person in accord-
ance with the latest IEE Wiring Regulaons.
Isolate mains supply before commencing installaon. Please read all
instrucons before proceeding.
Ensure that the fixed wiring connecons to the mains supply is via a
fuse rated at not more than 6 amps and class ‘A’ switch having a
contact separaon of a minimum of 3mm in all poles. The recom-
mended cable sizes are 1.0mm sqr or 1.5mm sqr.
No earth connecon is required as the product is double insulated
but ensure connuity of earth throughout the system.
If the unit is fied to a metal surface, IT IS ESSENTIAL that the metal
be earthed. DO NOT use a surface mounng box.
NEVER fit or remove the unit to a live wall-plate.
Maintenance
Always isolate the mains supply before commencing any work,
servicing or maintenance on the system. And please read all instruc-
ons before proceeding.
Arrange for an annual maintenance and inspecon schedule to be
carried out by a qualified person on every part of the heang and hot
water system.
WARNING!
ALWAYS ISOLATE THE AC MAINS SUPPLY BEFORE INSTALLING.
THIS PRODUCT MUST BE FITTED BY A QUALIFIED PERSON, AND
INSTALLATION MUST COMPLY WITH THE GUIDANCE PROVIDED IN
THE CURRENT EDITIONS OF BS767 (IEE WIRING REGULATIONS) AND
PART “P” OF THE BUILDING REGULATIONS.
13
Safety Noce
Technical Data