EN 20
TECHNICAL SPECIFICATIONS
Information according regulation (EU) 66/2014
Measurements according EN60350-2
Model identification
KI390ZT
Type of hob Induction hob
Number of electric cooking zones and/or areas 5
Heating technology Induction cooking
zones and cooking
areas
For circular electric cooking zones: diameter of useful surface area per
electric heated cooking zone in cm
17.5 21.5 26.7
Energy consumption per cooking zone or area calculated per kg (EC
electric
hob
) in Wh/kg
185.0 166.8 183.5
Energy consumption for the hob, calculated per kg (EC
electric cooking
)
in Wh/kg
177.4
Hob power configuration
The hob connecting power can be adjusted according to the power supply network.
Default factory setting is a 3 phase connection. When connecting to a 2 phase network the hob
power needs to be limited.
Adjust the hob power limitation
1. Touch and hold the timer key within 2 minutes after connection to the power mains.
2. Touch the minus (-) key while holding the timer key. You hear a audio signal.
3. Touch the front left cooking zone plus (+) key while holding the timer key.
▷ The front left cooking zone display show symbol (C).
▷ The rear left cooking zone display show the limitation zero (0) or one (1).
Configuration Power limitation Network connection
C0 = 0 10400 W 3 phase
C0 = 1 7400 W 2 phase
4. Touch the front left plus (+) key to change the power limitation.