23
2537376-01-04/21 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTP/CTA-L1/2-BR
EN
10.6. Connector assignment of safety switches CTP/CTA-…-BR-…-SAB-…
with plug connectors 2 x M12
Plug connector
(view of connection side)
Pin Designation Function
Conductor coloring of
connecting cable
1)
2 x M12
X2.5
X1.8
X1.5
X1.6
X1.7
X1.2
X2.4
X2.3
X2.1
X2.2
X1.4
X1.3
X1.1
X 1.1 FI1B Enable input, channel B WH
X 1.2 UB Electronics operating voltage, 24VDC BN
X 1.3 FO1A
Safety output, channel A
GN
X 1.4 FO1B
Safety output, channel B
YE
X 1.5 OL/C Guard lock monitoring output/communication GY
X 1.6 FI1A Enable input, channel A PK
X 1.7 0VUB Electronics operating voltage, 0V DC BU
X 1.8 RST Reset input RD
X 2.1 IMM Solenoid operating voltage, 0 V DC BN
X 2.2 OD Door position monitoring output WH
X 2.3 OI Diagnostic monitoring output BU
X 2.4 IMP Solenoid operating voltage, 24VDC BK
X 2.5 - n.c. GY
1) Only for standard EUCHNERconnecting cable.
10.7. Connector assignment of safety switches CTP/CTA-...-BR-...-AZDE-SAB-...
with plug connectors 2 x M12
Plug connector
(view of connection side)
Pin Designation Function
Conductor coloring of
connecting cable
1)
2 x M12
X2.5
X1.8
X1.5
X1.6
X1.7
X1.2
X2.4
X2.3
X2.1
X2.2
X1.4
X1.3
X1.1
X 1.1 FI1B Enable input, channel B WH
X 1.2 UB Electronics operating voltage, 24VDC BN
X 1.3 FO1A
Safety output, channel A
GN
X 1.4 FO1B
Safety output, channel B
YE
X 1.5 OD/C Door position monitoring output/communication GY
X 1.6 FI1A Enable input, channel A PK
X 1.7 0V Electronics and solenoid operating voltage, 0V DC BU
X 1.8 UA
Solenoid (auxiliary) voltage, 24VDC
(connected internally to UB)
RD
X 2.1 S1.A1 Emergency stop (channel A contact 1) BN
X 2.2 S1.B1 Emergency stop (channel B contact 1) WH
X 2.3 - n.c. BU
X 2.4 S1.A2 Emergency stop (channel A contact 2) BK
X 2.5 S1.B2 Emergency stop (channel B contact 2) GY
1) Only for standard EUCHNERconnecting cable.
10.8. Connector assignment of safety switches CTP/CTA-…-BR-…-SA-…
with plug connector M12, 8-pin
Plug connector
(view of connection side)
Pin Designation Function
Conductor coloring of
connecting cable
1)
1 x M12
8
5
6
7
2
4
3
1
1 FI1B Enable input, channel B WH
2 UB Electronics operating voltage, 24VDC BN
3 FO1A
Safety output, channel A
GN
4 FO1B
Safety output, channel B
YE
5 OD/C Door position monitoring output/communication GY
6 FI1A Enable input, channel A PK
7 0V Electronics and solenoid operating voltage, 0V DC BU
8 IMP Solenoid operating voltage, 24VDC RD
1) Only for standard EUCHNERconnecting cable.