14.4. Dimension drawing for safety switch CTP/CTA…
14.4.1. Dimension drawing for safety switch CTP…
44 / 74 / 94
35
40
14
144
30
<40>
34
h
Z
0,5
16
C
B
A
0,5
<42>
33
10
190
16,5
M12x1
41,5
37,5
X1
X2
Auxiliary
release
5.3 (4x), 1.4 Nm
for screw M5x35mm
DIN1207/ISO4762
Basic position for escape
release
Release by pressing
With escape release
M23x1
24
Version with plug connector M23 (RC18)
Version with plug connectors 2 x M12
Locking
screw
LEDs
The actuator shaft for the escape
release can be extended using exten-
sions (max. 94mm)