EasyManua.ls Logo

EUCHNER CTP - Connector Assignment of Safety Switches CTP;CTA; With Plug Connector M23 (RC18)

EUCHNER CTP
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
Transponder-Coded Safety Switch CTP/CTA-L1/2-BR
24
(translation of the original operating instructions) 2537376-01-04/21
10.9. Connector assignment of safety switches CTP/CTA-…-BR-…-SH-…
with plug connector M23 (RC18)
Plug connector
(view of connection side)
Pin Designation Function
Conductor coloring of
connecting cable
1)
M23 (RC18)
With shield
spring
18
19
15
12
11
9
5
4
3
2
1
17
16 14
13
6
10
8
7
1 IMP Solenoid operating voltage, 24VDC VT
2 FI1A Enable input, channel A RD
3 FI1B Enable input, channel B GY
4 FO1A
Safety output, channel A
RD/BU
5 FO1B
Safety output, channel B
GN
6 UB Electronics operating voltage, 24VDC BU
7 RST Reset input GY/PK
8 OD/C Door position monitoring output/communication GN/WH
9 OI Diagnostic monitoring output YE/WH
10 OL Guard lock monitoring output GY/WH
11 - n.c. BK
12 FE
Functional earth
(must be connected to meet the EMC requirements)
GN/YE
13 - n.c. PK
14 - n.c. BN/GY
15 - n.c. BN/YE
16 - n.c. BN/GN
17 - n.c. WH
18 IMM Solenoid operating voltage, 0V DC YE
19 0VUB Electronics operating voltage, 0V DC BN
1) Only for standard EUCHNERconnecting cable.

Table of Contents