Operating Instructions Safety Systems
MGB-L0…-AR.-… and MGB-L0…-AP.-…
32
(translation of the original operating instructions) 112657-12-01/15
13. Technical data
NOTICE
If a product data sheet is included with the product, the information on the data sheet applies in case
of discrepancies with the operating instructions.
Parameter Value Unit
Housing material Glass ber reinforced plastic;
die-cast zinc, nickel-plated;
stainless steel
Dimensions See chapter 7.4. Dimension drawing on page 12
Weight
Interlocking module
Handle module
Escape release
0.75
1.00
0.50
kg
Ambient temperature at U
B
= DC24V -20 … +55 °C
Degree of protection
Cover not populated/populated with buttons/indi-
cators/selector switches
Cover populated with key-operated rotary switch
Cover populated with key-operated rotary switch FS22
IP 65
IP 54
IP 42
Safety class III
Degree of contamination 3
Installation position Any
Connection 4 cable entries M20x1.5 or plug connector
Conductor cross-section (rigid/exible)
- With ferrule according to DIN46228/1
- With ferrule with collar according to DIN46228/1
0.13 … 1.5 (AWG 24 … AWG 16)
0.25 … 1.5
0.25 … 0.75
mm²
Operating voltage UB
(reverse polarity protected, regulated, residual
ripple <5%)
24 +10% / -15% (PELV) V DC
Auxiliary voltage UA
(reverse polarity protected, regulated, residual
ripple <5%)
24 +10% / -15% (PELV) V DC
Current consumption I
UB
(no load on any outputs) 80 mA
Current consumption I
UA
- Push button S (unloaded, per LED) 5
mA
External fuse See chapter 11.3. Fuse protection for power supply on page 22
Safety outputs FO1A/FO1B Semiconductor outputs, p-switching, short circuit-proof
Test pulses AR <1,000/AP <300 µs
Test pulse interval Min. 100 ms
Output voltage U
FO1A
/ U
FO1B
1)
HIGH U
FO1A
/ U
FO1B
U
B
-2V … U
B
LOW U
FO1A
/ U
FO1B
0 … 1 V DC
Switching current per safety output 1 … 200 mA
Utilization category according to ENIEC60947-5-2 DC-13 24 V 200 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.
Monitoring outputs
- Output voltage
1)
- Max. load
p-switching, short circuit-proof
U
A
- 2V … U
A
Max. 50 mA
Rated insulation voltage U
i
30 V
Rated impulse withstand voltage U
imp
1.5 kV
Resilience to vibration In acc. with ENIEC60947-5-3
Switching frequency 0.25 Hz
EMC protection requirements In acc. with ENIEC60947-5-3
Reliability values acc. to ENISO13849-1
Category 4
Performance Level PL e
PFH
d
3.7 x 10
-9
/ h
2)
Mission time 20 years
B
10d
(emergency stop) 0.065x10
6
Emergency stop
Operating voltage 5 … 24 V
Operating current 1 … 100 mA
Breaking capacity max. 250 mW
Power supply LED 24 V DC
Controls and indicators
Operating voltage UA V
Operating current 1 … 10 mA
Breaking capacity max. 250 mW
Power supply LED 24 V DC
1) Values at a switching current of 50 mA without taking into account the cable length.
2) Applying the limit value from ENISO13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), the employers’ liability insurance association certies a PFHd of max. 2.47 x 10
-8
.