Operating Instructions Safety Systems
MGB-L0…-AR.-… and MGB-L0…-AP.-…
32
(translation of the original operating instructions) 112657-12-01/15
13. Technical data
NOTICE
If a product data sheet is included with the product, the information on the data sheet applies in case
of discrepancies with the operating instructions.
Parameter Value Unit
Housing material Glass ber reinforced plastic;
die-cast zinc, nickel-plated;
stainless steel
Dimensions See chapter 7.4. Dimension drawing on page 12
Weight
Interlocking module
Handle module
Escape release
0.75
1.00
0.50
kg
Ambient temperature at U
B
= DC24V -20 … +55 °C
Degree of protection
Cover not populated/populated with buttons/indi-
cators/selector switches
Cover populated with key-operated rotary switch
Cover populated with key-operated rotary switch FS22
IP 65
IP 54
IP 42
Safety class III
Degree of contamination 3
Installation position Any
Connection 4 cable entries M20x1.5 or plug connector
Conductor cross-section (rigid/exible)
- With ferrule according to DIN46228/1
- With ferrule with collar according to DIN46228/1
0.13 … 1.5 (AWG 24 … AWG 16)
0.25 … 1.5
0.25 … 0.75
mm²
Operating voltage UB
(reverse polarity protected, regulated, residual
ripple <5%)
24 +10% / -15% (PELV) V DC
Auxiliary voltage UA
(reverse polarity protected, regulated, residual
ripple <5%)
24 +10% / -15% (PELV) V DC
Current consumption I
UB
(no load on any outputs) 80 mA
Current consumption I
UA
- Push button S (unloaded, per LED) 5
mA
External fuse See chapter 11.3. Fuse protection for power supply on page 22
Safety outputs FO1A/FO1B Semiconductor outputs, p-switching, short circuit-proof
Test pulses AR <1,000/AP <300 µs
Test pulse interval Min. 100 ms
Output voltage U
FO1A
/ U
FO1B
1)
HIGH U
FO1A
/ U
FO1B
U
B
-2V … U
B
LOW U
FO1A
/ U
FO1B
0 … 1 V DC
Switching current per safety output 1 … 200 mA
Utilization category according to ENIEC60947-5-2 DC-13 24 V 200 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.
Monitoring outputs
- Output voltage
1)
- Max. load
p-switching, short circuit-proof
U
A
- 2V … U
A
Max. 50 mA
Rated insulation voltage U
i
30 V
Rated impulse withstand voltage U
imp
1.5 kV
Resilience to vibration In acc. with ENIEC60947-5-3
Switching frequency 0.25 Hz
EMC protection requirements In acc. with ENIEC60947-5-3
Reliability values acc. to ENISO13849-1
Category 4
Performance Level PL e
PFH
d
3.7 x 10
-9
/ h
2)
Mission time 20 years
B
10d
(emergency stop) 0.065x10
6
Emergency stop
Operating voltage 5 … 24 V
Operating current 1 … 100 mA
Breaking capacity max. 250 mW
Power supply LED 24 V DC
Controls and indicators
Operating voltage UA V
Operating current 1 … 10 mA
Breaking capacity max. 250 mW
Power supply LED 24 V DC
1) Values at a switching current of 50 mA without taking into account the cable length.
2) Applying the limit value from ENISO13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), the employers’ liability insurance association certies a PFHd of max. 2.47 x 10
-8
.