Operating Instructions Safety Systems
MGB-L0…-AR.-… and MGB-L0…-AP.-…
8
(translation of the original operating instructions) 112657-12-01/15
3. Description of the safety function
Devices from this series feature the following safety functions:
Monitoring of the safety guard position
(interlocking device according to ENISO14119)
Ì Safety function: The safety outputs are switched off when the safety guard is open (see chapter 6. Function on page
10).
Ì Safety characteristics: category, Performance Level, PFH
d
(see chapter 13. Technical data on page 32).
The following applies to devices with emergency stop:
Emergency stop
(emergency stop device according to ENISO13850)
Ì Safety function: emergency stop function
Ì Safety characteristics: B
10d
value (see chapter 13. Technical data on page 32)