EV-97 Eurostar SL Microlight Maintenance Manual GEN/EUR/04 Issue 4 42
Appendix 1 - Levelling Record
Model:
EV-97 Eurostar
SL Microlight
Registration:
G-
S/N:
Vertical measurement
Straight measurement
Differences left / right side
Point Measure
Points Measure
Specified values Actual
1
1-13
Points
Difference
Tolerance
Difference
2
3-15
1-3
0
±0.08 in
3
6-17
2-4
±2 mm
4
8-17
1-2
0
±0.08 in
5
13-18
3-4
±2 mm
6
15-18
5-6
0
±0.2 in
7
7-8
±5 mm
8
9-10
0
±0.1 in
9
11-12
±3 mm
10
5-9
11
7-11
136 mm
±0.4 in
12
6-10
5.35 in
±10 mm
13
8-12
14
13-15
0
±0.4 in
15
14-16
±10 mm
16
1-13
0
±0.8 in
17
3-15
±20 mm
6-17
0
±0.8 in
8-17
±20 mm
13-18
0
±0.4 in
15-18
±10 mm