5 HOMEDEPOT.COM
Please contact 1-844-883-1872 for further assistance.
Pre-Installation (continued)
ELECTRICAL REQUIREMENTS
□
Connect the pump to an individual branch circuit with no other outlets or equipment in
the circuit.
□ Size fuses or circuit breakers according to this chart:
HP Voltage Individual Branch Circuit Required (Amps)
1/2 115 15
PERFORMANCE CHART
SKU HP GPM of Water @ Total Feet of Lift Max. Lift
0 ft. 5 ft. 10 ft. 15 ft. 20 ft.
1/2 64 58 53 47 40 38 ft.
SPECIFICATIONS
Power supply
115 V, 60 Hz, 15 Amp circuit
Liquid temperature range
32º – 131ºF (0º – 55ºC)
Discharge size
2 in. FNPT
Sump basin
Minimum 18 in. (460 mm) diameter, 30 in. (760 mm) depth
Switch on/off
ON: 17 in., OFF: 9.91 in.
TOOLS REQUIRED
Flathead
screwdriver
Phillips
screwdriver
Safety goggles Cable Ties
Pipe wrench Channel locks Tape measure Hacksaw
1004 118 476