We appreciate t
he trust and confidence you have placed in Everbilt through the purchase of this sump pump. We strive to continually create quality
products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for
choosing Everbilt!
Item #1000 041 119
1000 041 120
Model #HDS30
HDS50
USE AND CARE GUIDE
SUMP PUMP
Questions, problems, missing parts? Before returning to the store,
call Everbilt Customer Service
8 a.m. - 6 p.m., EST, Monday-Friday
HOMEDEPOT.COM
1-844-883-1872

Questions and Answers

  • S
    Stanley Sparks DVMJul 25, 2025
    How to troubleshoot Everbilt HDS50 Water Pump that does not turn on?
    • B
      bjonesJul 25, 2025
      If your Everbilt Water Pump isn't turning on, start by ensuring it's properly plugged in. Then, check your circuit breaker to see if it has tripped or if a fuse is missing and replace the fuse or turn on the breaker if necessary. Also, make sure that the float is free of debris and obstructions. If these steps don't resolve the issue, the switch or the motor may be defective, requiring service by an authorized service center.
  • J
    John FloresJul 31, 2025
    What to do if Everbilt HDS50 runs but does not discharge liquid?
    • R
      Robert RoseJul 31, 2025
      If your Everbilt Water Pump runs but doesn't discharge liquid, start by checking the check valve to ensure it's correctly installed with the flow indicating arrow pointing in the right direction. Also, the check valve might be stuck or plugged, so remove it and inspect it for proper operation. Another potential issue is that the lift might be too high for the pump's capacity, so check the rating table. Lastly, the inlet to the impeller could be plugged, requiring you to pull the pump and clean it. If the pump is air locked, shut the power off for approximately 1 minute and restart. Repeat several times to clear air from the pump.
  • G
    George KelleyAug 7, 2025
    Why Everbilt Water Pump will not shut off?
    • J
      Joseph GonzalezAug 7, 2025
      If your Everbilt Water Pump won't shut off, there might be an obstruction in the float or float rod path, so check and clear any obstructions. Another potential cause is the pump being air locked; try shutting off the power for about a minute and then restarting it, repeating this several times. Also, if the liquid inflow matches the pump capacity, a larger pump might be necessary. If none of these solutions work, the switch might be defective, and you should have the pump serviced by an authorized service center.
  • M
    Matthew Rodriguez MDAug 12, 2025
    What to do if Everbilt Water Pump does not deliver the rated capacity?
    • R
      Russell LoweAug 12, 2025
      If your Everbilt Water Pump isn't delivering its rated capacity, first check the rated pump performance to ensure the lift isn't too high for the pump. Next, verify that the supply voltage corresponds to the voltage on the nameplate, as low voltage can slow the speed. Additionally, the impeller or discharge pipe could be clogged, so pull the pump and clean it, checking the pipe for scale or corrosion. Finally, if the impeller is worn due to abrasives, consider replacing it.
  • M
    Michael CastilloAug 18, 2025
    Why does my Everbilt HDS50 continually cycle?
    • T
      Timothy ReillyAug 18, 2025
      If your Everbilt Water Pump continually cycles, it might be due to the absence of a check valve in the long discharge pipe, which allows liquid to drain back into the sump. In this case, install a check valve in the discharge line. Alternatively, the existing check valve might be leaking, so inspect it for correct operation. Lastly, if the basin is too small for the inflow, consider installing a larger basin.

Summary

Safety Information

Precautions

Read instructions carefully, do not restrict intake, avoid running dry, and prevent freezing.

Electrical Safety

Electrical Safety Guidelines

Check voltage, use 3-prong plug, do not use extension cords, and ensure proper wiring connection.

Pre-Installation Steps

Installation Requirements Checklist

Install with float switch, in a suitable basin, on a hard level surface, and use appropriate piping and check valve.

Installation Process

Operation Guide

Troubleshooting

Pump Does Not Turn On

Check power connection, circuit breaker, float obstruction, or motor defects.

Pump Will Not Shut Off

Check for float obstruction, air lock, or defective switch or pump.

Pump Runs But No Discharge

Verify check valve installation, check for blockage, or air lock.