Pickup device: | SONY 1/3” interline transfer color EXView CCD |
---|---|
Sensitivity: | 0.1 lux / F=1.2 |
Vari-Focal Lens: | 3.6-9mm / 9-22mm IR Lens |
IR Cut Removable: | Yes (Auto IR Cut Removable and B/W Sensitivity Enhanced) |
Electronic shutter: | Up to 1/100, 000 |
IRIS Control: | Auto |
Auto white balance: | YES |
Auto gain control: | ON/OFF switch |
Back light comp.: | ON/OFF switch |
Picture element: | NTSC: 768(H) × 494(V) PAL: 752(H) × 582(V) |
Gamma correction: | 0.45 |
Video output: | 1.0Vp-p, 75ohm |
Horizontal Resolution: | 520 TV Lines |
S/N ratio: | >52dB(AGC off) |
Line Lock: | ON/OFF switch for 24V AC |
Flickerless: | ON/OFF switch |
Sync. mode: | Internal Sync. /Line lock (Only for AC24V) |
Weatherproof Ratings: | IP66 |
Heater auto activated temperature: | 50 degree Fahrenheit |
Operating temperature: | -40 ~ 122 degrees Fahrenheit, 20~80% |
Power source: | 12V DC+/-10%, 24V AC+/-10% |
Power Consumption: | 5W Max. (15W when heater active; thermostatically controlled) |
Dimension: | 5.1” (W) x 3.9” (H) x 5.1” (D). |
---|---|
Weight: | 3.7 lbs |
Install camera away from devices generating magnetic fields to prevent video distortion.
Avoid installing camera in high temperatures to prevent deformation or discoloration.
Never aim the camera at the sun or extremely bright objects to prevent damage.
Use a soft cloth for the body; lens tissue/applicator with ethanol for CCD sensor and lens.
Heater elements can be very hot; do not touch while active.
Loosen 4 screws, carefully uncap housing cover, and remove hinges.
Unplug wire, loosen 2 screws, push base to remove camera from mounting base.
Attach base to wall/ceiling using 4 setscrews; ensure mounting is strong enough for camera weight.
Align camera with 'Wall' or 'Ceiling' markers on lead frame during re-assembly.
Connect power, video, and alarm outputs to the termination board connectors.
Rotate camera for 360° horizontal, 140° vertical, 60° 3'rd axis view; adjust focus/zoom if needed.
Reposition adjustment stick to the right-hand hole to avoid obstructing other adjustments.
Controls vertical synchronization using internal time base or AC signal in power lines.
Adjusts signal strength sensitivity automatically for varying light conditions.
Compensates for subjects with bright backgrounds by averaging center area light.
Stabilizes electronic shutter speed to reduce picture flicker in varying light.
Adjusts brightness level by turning the IRIS level VR clockwise for brighter picture.
Selects light metering method (Average or Peak) by adjusting the IRIS ALC VR.
Place desiccant pack on horizontal rod and bend rod to fix after setting adjustments.
Install the outer cover and tighten the screws to complete the installation process.