Temporized Blast Cycle
Press key temporized freezing
to select a negative temperature temporized Blast.
The led temporized freezing is on
.
The display DIS1 shows up the set point cold room wile the display DIS2 shows up three dots,
With keys “More
and Less
” is possible change the set point of the cold room.
Press the key START/STOP
to the start on of the cycle.
NOTE: the values degrees settable for the cold room are from -40°C until 99°C. the lower and highest minutes value
settable are from 0 to 400 minutes..
Hard Blast Cycle
Press the key hard
to select an Hard blast cycle
This kind of cycle is divided in two phases with two different set points.
The cycle selected is controlled by the core probe, from default.
The hard
and temperature
led’s are light on, the display DIS1 shows the first phase cold room set point wile
the display DIS2 shows three dashes .
With keys more or less
is possible change the set point.
To change the cold room set point II phase, press the key Hard
for at least 5 seconds.
The led Hard
blinking and the display DIS1 shows the cold room set point second phase.
To commute the cycle in to a temporized cycle, press key Time
.
The display DIS2 shows up the time, use keys more
or less
to change the value, that can not overcome the
parameters in precedence settle because it defines the complete durability of all the blast hard cycle.
The changes applied are only temporary and don’t remain in memory.
Press key START/STOP
to the start on.
NOTE: The minimum settable value for the cold room set point is -40° C and the maximum is 99° C. The minimum set-
table time value is 0 minutes.