Number Module /
Unit
Info Message Explanations / Remedies
W-002 Hydraulic
module
Cameo: Coee
boiler is
heating...
Enigma /
Shotmaster /
E'line: Coee
boiler left is
heating...
If this message remains,
contact service organisation.
- -
W-003 Hydraulic
module
Enigma /
Shotmaster /
E'line: Coee
boiler right is
heating...
Contact service organisation. - -
W-004 Hydraulic
module
Water ow left
too low.
Contact service organisation. -
W-005 Hydraulic
module
Water ow right
too low.
Contact service organisation. -
W-006 Cleaning
balls
dispenser
Check cleaning
ball dispenser.
• Blocked or
broken
cleaning
balls?
• Light barrier
dirty?
Contact service organisation. -
W-007 Cleaning
balls
dispenser
The coee
machine has
been cleaned
without
cleaning balls.
• Cleaning ball
dispenser
empty?
• Blocked or
broken
cleaning
balls?
This warning is set, if
no cleaning ball has been
detected.
Check if the cleaning ball
dispenser is empty. If yes, rell
it.
Check if a cleaning ball is
blocking the dispenser.
If this message remains,
contact service organisation.
-
W-008 Display /
Touch
screen
Press Continue
to start the
cleaning now. If
you want to
start the
cleaning later,
push the Cancel
button in the
upper right
corner.
To start cleaning later, press
and hold the Rinse key for ve
seconds to start cleaning.
- -
Troubleshooting