R410A 60Hz EER 2.36 Series Service Manual
Pressing this key in the other modes, the wind speed switches by "automatic wind speed, low speed, middle speed,
high speed, automatic wind speed " circularly.
Timer
Under the shutdown state, press this key to set the opening time, range from 1 hour to 24 hour.
Under the boot state, press this key to set the shutdown time, range from 1 hour to 24 hour.
The timing time is according to the cycle of "1h, 2h, ……, 23h, 24h, cancel, 1h".
Exit timing adjustment after 3 seconds without key pressing.
TURBO
Extension code remote controller has the effect. The remote controller is no TURBO by default, and the TURBO
key will not wo
rk in automatic mode, dehumidification mode and fan mode.
Pressing this key in the cooling or heating mode, the TURBO mode switches between opening and closing. When
in the TURBO mode, it does not display the wind speed. Switching mode or entering sleep function will close
TURBO mode.
If the air conditioner has four gear wind speeds, the TURBO icon will light up and the fan will run in the fourth
gear wind speed by pressing this key.
ECON
The remote controller is no ECON by default, and the ECON key will not work in automatic mode,
dehumidification
mode and fan mode.
Pressing this key in the cooling or heating mode, the ECON mode switches between opening and closing. When in
the ECON mode, the setting temperature is set to 26
(77 ) and other settings are unchanged. If closing ECON
mode, the remote controller will recover to the setting before opening ECON mode. Switching mode will close
ECON mode.
Sleep
Pressing this key in the modes except of the fan mode, the sleep function switches between opening and closing.
Switching mode will cancle sleep function.
When pressing this key, the wind speed is automatically switched to low wind. However, the wind speed can be
adjusted according to the wind speed key (except of the dehumidification mode).
Light
When the first power on, there is no lampligh
t by default. Pressing this key force to turn off or turn on the lamplight.
Decide whether to have this function according to the actual model.
Clock
This key is used to set the clock. Pressing enters the hour adjustment state, and the hour digital tube on the LCD is
flickering at the same time. The hour can be set by temperature addition or reduction keys, and it ranges from 0 to
23.
When the hour is set, press this key again to enter the minute adjustment state, and the minute digital tube on the
LCD is flickeri
ng at the same time. The minute can be set by temperature addition or reduction keys, and it ranges
from 00 to 59.
After adjusting, press the clock key again to confirm the setting and the adjustment state exits. If do not press the
clock key again to confirm, the time adjustment state will exit after 3 seconds, and recover the clock before the
adjustment.
Lock
There is no lock by default. Pressing this key, the lock function switches between opening and closing.
When it is locked, the remote controller does not work except the lock key.
Combinatorial key: “FAN -”
“FAN +”
Extension code remote controller has the effect. Switch 3 gear wind and 6 gear wind. There is 6 gear wind on the
LCD. If the 3 gear wind is switched, the first and second gear wind will be "low wind"; the third and fourth gear
wind will be "middle wind"; the fifth and sixth gear wind will be "high wind".
Combinatorial key: “Mode”
“Lock”
Enter address setting
On the shutdown interface, press the combinatorial key on the remote controller for 5 seconds to enter the address
setting interface.
The last address (when the first power on, 00 is displayed) and the "#" icon are displayed and flickering.
The step instructions of setting address
At the address setting interface, press the temperature addition or reduction to adjust the setting address, and it
ranges from 00 to 63.
When the first time entering the interface or pressing the temperature addition or reduction key, the address
display
flickers for 3 seconds and then does not flicker.
Press the ON / OFF key to enter the sending state and send the address setting code.
The step instructions of inquiring address
At the address setting interface, press the mode key to send the query code.
At this time, the "#" icon flickers. 3 seconds later, it normally displays the last setting addresses and the "#" icon