HARDWARE
Clock Source controls from which source the SP8 will take its clock. Internal will
use the built-in clock, Digital will take the clock from the ADAT data the unit
receives from the Optical Inputs and Word Clock takes the clock from the BNC
Word Clock Input.
When the Digital or Word Clock source is selected, the sample rate will
automatically be set to AUTO mode. This allows the SP8 to follow the sample
rate of the Clock Source.
Here you can select the sample rate you wish the device to operate at. If you are
using an external clock source (Digital or Word Clock), you can set this to AUTO
and the sample rate will be automatically adjusted to match the incoming
clock signal.
This allows you to change whether or not the Word Clock Input is terminated
or not. The Word Clock Termination should be turned on if the SP8 is the last
device in a Word Clock Chain. If you are using a BNC T-Connector to send the
clock onwards to another device then set the termination to o.
It is important to get your Word Clock Termination correct as it can stop your
devices from correctly synchronising.
Clock source
Sample rate
Word clock