Temperature Current Limit Thresholds
The charger monitors its internal temperature at two locations. If
the temperature exceeds values considered to be dangerous to
the electronics and safety, the charger will first limit its maximum
charging current to lower its power dissipation. If the temperature
still increases beyond that set-point (79°C), the charger will stop
the session and enter a “Fault” state.
Temperature, °C
Current limit, A per phase
72
31.8
73
29.4
74
26.8
75
24
76
20.8
77
17
78
12
79
6