7
ENGLISH
391 AUTOMATED SYSTEM
The 391 automated system consists of a non-reversing electro-
mechanical operator available in two versions:
• 391 E with built-in control unit
• 391 without control unit
The operator was designed for automating the opening of gates
with one or two leaves, with maximum length of 2.5m.
A handy, safe releases system, with personalised key, moves the
leaf in case of a power cut or fault.
The two articulated arms are designed for moving gates with
very large pilasters. The distance between the hinge and the
gearmotor securing point can be up to 220 mm. Thanks to the
special geometry of the two arms, all possible shearing points
have been eliminated.
• Correct operation and the specifications declared
in these instructions can be obtained only with
FAAC
accessories and safety devices.
• To make an installation conforming to current safety
regulations, the absence of a mechanical anti-crushing
clutch, means that a control unit with an adjustable
electronic clutch device is necessary.
• The 391 automated system was designed and built for
controlling vehicle access - do not use for any other
purpose.
1 Gearmotor
2 Transformer
3 Control unit (for master motor only)
4 Release device
5 Receiver module (optional)
6 Mechanical stops
7 Transmission arm
8 Covering housing
9 Rear bracket
10 Lower housing
2. TECHNICAL SPECIFICATIONS
MODEL 391 E 391
Power supply 230 V~ -
Electric motor 24 Vdc 24 Vdc
Absorbed power 120 W 110 W
Max torque 250 N/m 250 N/m
Max angular speed 13 °/sec 13 °/sec
Max leaf
1-2
2.5 m 2.5 m
Max leaf weight
2
See graph
Use frequency at 20°C 80 cycles/day 80 cycles/day
Consecutive cycles at 20°C 30 30
Mximum continuous opera-
ting time
O.T. 17 min.
Protection Class IP44 IP44
Operating ambient tempe-
rature
-20°C +55°C -20°C +55°C
Noise level <70 dB (A)
Operator weight 8.7 Kg 7 Kg
Dimensions See fig. 2
1
For leaves with a length L>2m, an electric lock must be installed
to guarantee locking the leaf.
2
The weight P of the leaf is a function of the length L. Check if your
leaf is in the zone shown in the graph underneath.
3. DIMENSIONS
1. COMPONENTS
FIG. 1