9
FAAC 400 Hydraulic Swing Gate Operator
4. START-UP
The Model 400 has an anti-crushing safety device which limits the
operators force when an obstacle is encountered while the gate
is moving. To adjust the intervention threshold of the anti-crushing
system, temporarily open the release cover.
Lift the protective cap (Fig. 13, Ref.1) and insert the supplied
key (Fig. 13, Ref. 2).
Turn the key 90°clockwise to open the cover.
Lift the cover (Fig. 14).
Remove the screw (Fig. 14, Ref. 3) which secures the knob
and then remove the knob (Fig. 14, Ref. 4).
Locate the force adjustment screws (By-Pass) on the operator
(Fig. 14, Ref. 5 and 6) .
OPEN pressure screw (green wording): gate opening
direction.
CLOSE pressure screw (red wording): gate closing
direction.
To reduce torque, turn screws counter-clockwise.
To increase torque, turn screws clockwise.
When you have nished making adjustments, re-position the
knob (Fig. 14, Ref. 4) and tighten the screw (Fig. 14, Ref. 3).
Close the cover and lock it by turning the key counter-
clockwise.
Figure 11 Figure 13
Figure 12
Connect the power cable to the operator and fasten the
screws (Figure 14A).
5. FINAL OPERATIONS
Finish the installation procedure as follows:
Close the cover of the release device with the key.
Remove the vent screw (Fig.12, Ref. 2).
Figure 14
Figure 14A
Anti-Crushing System Adjustments
WARNING: Do not overtighten the screws to
compensate for a damaged gate.
WARNING: Failure to remove the vent screw may result in
erratic operation.