Figure A
F
F1
F2
J1
J2
J3
J4
J5
J6
DL
–
+
Power Supply 115 V~ ± 10% or 230 V~ +6% -10% 50/60 Hz
Absorbed Power 10 W
Motor Max. Load 800 W
Accessories Max. Load 0,5 A
Electric Lock Max. Load 15 VA
Ambient Operating Temperature Range -4°F to +131°F
Protection Fuses 2 (see Fig. A)
Function Logics: Semi-automatic / Automatic / Safety Devices /
“Stepped” Semi-automatic / “Stepped” Automatic / “Stepped” Safety
Devices / Semi-automatic B / Dead-man C
Opening/Closing Time Programmable (from 0 to 120 s)
Pause Time Programmable (from 0 to 4 min.)
Closing Leaf Delay Programmable (from 0 to 4 min.)
Opening Leaf Delay 2 s (can be excluded)
Thrust Force: Adjustable on 50 levels for each motor
Terminal Board Inputs: Open / Open Free Leaf / Stop / Limit-switch
Opening Safety Devices / Closing Safety Devices / Power Supply +
Earth.
Terminal Board Outputs: Flashing Lamp / Motors / 24 VDC Acces-
sories Power Supply / 24 VDC Indicator-Light / Fail Safe / 12 VAC
Electric Lock Power Supply
Programmable Functions: Logic / Pause Time / Thrust Force / Torque
at Initial Thrust / Opening and Closing Leaf Delay / Reversing Stroke
/ Over-Pushing Stroke / Indicator-Light / Pre-Flashing / Electric Lock /
Fail Safe / Safety Devices Logic / Assistance Request / Detection Time
of Obstacle or Contact Point
Learning Function: Simple or complete work time learning, with or
without Limit-switch and/or Gatecoder.
13.2. Technical Specications
13.1 455 D Control Board Warnings
Please refer to Chapter 16 for AC power wiring
guidelines
DL SIGNALLING AND PROGRAMMING DISPLAY
J1 LOW VOLTAGE TERMINAL BLOCK
J2 CONNECTOR FOR RP RECEIVER
J3 AC POWER SUPPLY TERMINAL BLOCK
J4 MOTORS AND FLASHING LAMP CONNECTION TERMINAL BLOCK
J5 INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BLOCK
J6 LIMIT-SWITCH AND GATECODER TERMINAL BLOCK
F1 MOTORS AND TRANSFORMER PRIMARY WINDING
FUSE (F 5A - 230V) (F 10A - 115V)
F2 LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F “F” PROGRAMMING PUSH-BUTTON
– “–” PROGRAMMING PUSH-BUTTON
+ “+” PROGRAMMING PUSH-BUTTON
24 VDC
3W
12 VAC
FCC2
LIMIT-SWITCH
OR GATECODER
230 VAC
50 Hz
or
115 VAC
60 Hz
VAC MAX.
60W
OPEN A
OPEN B
STOP
BLUE
BLUE
For connection
of the photo-
cells and safety
devices, see
Section 13.4.1.