Page 4
August, 2002
402 Installation
TECHNICAL DATA
T
HE 402 COMPACT OPERATOR
Parameter 402 Operator
Physical dimensions:
Weight, lb (kg) 14-1/3 (6.5)
Length, in. (mm) 36 (914)
Width ´ height, in. (mm) 3-1/2 ´ 3-1/2 (90 ´ 90)
Motor speed, rpm 1400
90-deg opening time, sec 12
Thrust and traction force, lb (kg) 0–1100
Maximum duty cycle, motor run time 50%
Power voltage required, VAC
(frequency, Hz)
1
115 (50–60)
+
10% or
230, +6 or -10% (50–60)
1
Current draw, amps
115 VAC power source 2.4
220 VAC power source 1.2
Operating temperature range, deg F (deg C)
-4 to 131 (-20 to 55)
Thermal cut out, deg F (deg C) 212 (100)
Oil quantity, qt (liter) 1-1/2 (1.4)
Oil type FAAC XD 220 or Shell/Tellus 15
Gate leaf constraints
Maximum weight per leaf, lb (kg) 900 (410)
Maximum length per leaf, ft (m) 10 (3)
1
Your standard 220 VAC power source meets the specification for the required
power supply of 230 VAC, +6 or –10%.
THE CONTROL PANEL
The 402 Operator must be installed with a 450 MPS
control panel to be a U.L. recognized installation. The
450 MPS can be used to control a single 402 operator
or a dual (bi-parting) system. Both the control panel
and the operator must use the same power supply
voltage.
THE 450 MPS
To determine the voltage requirement of your 450 MPS
control panel, refer to the label on the transformer of
the control panel:
Label reads: 1450MPSUS = 220 VAC
1450MPSUS115 = 115 VAC
Operating logics available: E, EP, A, S, B, and C