If the gate needs to be moved manually due to power outage
or an operator malfunction, proceed as follows:
1. Turn power off at the main breaker (even in the event of
a power outage).
2. Slide the protective cap, Fig. 21, Ref. 1.
3. Insert the key and turn it 90°, Fig. 21, Ref. 2.
4. To release the operator, turn the control lever 180° in the
direction indicated by the arrow on the release system,
Fig.21, Ref. 3.
5. Now the operator is released. The gate can be opened
and closed manually.
Note: To keep the operator in manual mode, the control lever
should be left in its current position (turned 180˚) and main
power should be kept off.
3.1 Restoring Normal Operation
To restore normal operating conditions, proceed as follows:
1. Turn the release system’s control lever 180° in the opposite
direction of the arrow.
2. Turn the release key 90° and remove it.
3. Close the protection cover.
4. Power up the system and perform a complete cycle of
movement to check that the automated system is cor-
rectly restored and all the safeties are operating properly
3. MANUAL OPERATION
4. MAINTENANCE AND REPAIRS
Periodically check the gate structure and ensure in particular
that the hinges are in perfect working condition.
Check that the electronic force setting on the control board is
adjusted correctly and that the manual release mechanism is
fully functional.
Safety devices installed on the system must be checked every
six months.
Repairs
For repairs, refer to FAAC authorized service centers.
11
Fig. 21
NOTE: If you wish to eliminate the slow-down in some stages,
you must supply an Open pulse within 1 second of
reaching the limit-switch.
If only one leaf is present, the entire sequence must executed,
as if the second leaf is present. When the leaf 1 has finished
opening, supply 5 Open pulses until the leaf begins to close,
and then resume the normal programming sequence.