11. Disengage the operator’s manual release and check
that the gate opens and closes smoothly, without extra
friction or resistance. Ensure that it opens and closes
completely, up to the travel limits.
12. Detach the operator from the front bracket and per-
menantly weld the bracket to the gate.
If the leaf structure prevents the bracket from being welded,
screw it to the leaf with adequate hardware.
Note: Grease all fastening pins of the fittings.
2.4 Wiring the Operator
A terminal block is available in the lower part of the operator
to connect the motor and the limit switches.
IMPORTANT : Use the supplied cable or a similar UL ap-
proved cable for outdoor use.
Motor Wiring Instructions:
1. Open one of the pre-drilled holes in the terminal block
cover, see Fig.13.
2. Mount the supplied strain relief.
3. Thread the two conductor cable through the strain relief
and connect the wires as shown in Fig.14.
Close and secure the cover with the four supplied screws
(Fig. 17).
Limit Switches wiring instructions:
Limit switches are wired in the same terminal block where
the motor wiring has been installed. Wire the limit switches as
follows:
1. Open the second pre-drilled hole in the cover, see Fig.
15.
2. Mount the supplied strain relief.
3. Thread the three conductor cable through the strain
relief and connect the wires as shown in Fig.16.
9
Fig. 14
Fig. 15
Fig. 16
POS. COLOR DESCRIPTION
1 White Common
2 Red Closing Limit Switch (FCC)
3 Black Opening Limit Switch (FCA)
Fig. 17
Fig. 13
POS. COLOR DESCRIPTION
1 White Common
2 Red Motor Phase 1
3 Black Motor Phase 2
T Yellow / Green Ground