13
7
6
5
4
3
2
1
9
8
N
L
J5
M
X
J6
25 µF capacitor
220 VAC ±10%, 50–60 Hz
FAAC lamp, 220 VAC
Common
N.O. activating device
N.C. stop device
N.C. reversing device
0 VDC
30 VDC
0 VDC, pulsed
Radio Receiver
123
Blue
Figure 13. The wiring diagram for the 746 MPS control panel
Set the DIP Switches
WARNING! Turn the main power off before you
make any electrical connections or set any DIP
switches on the control panel.
You need to set five DIP switches for the proper
operation of your gate site. After you set the switches be
sure to turn on the power and then press the reset button
on the control panel so that the settings you have made
take effect.
Note: DIP switch 6 is not used on the 746 MPS
control panel.
Set DIP switches 1 and 2 for logic, switches 3 and 4 for
pause time, and switch 5 for warning light function as
shown in the following tables.
Note: Be sure to press the Reset button after you
have made your DIP switch settings.
Logic Settings
DIP Switch
Logic 1 2
E1 On On
E2 On Off
A1 Off On
A2 Off Off
Pause Time Settings
DIP Switch
Pause Time 3 4
5 sec On On
10 sec Off On
30 sec On Off
120 sec Off Off