8
Logic E1
Gate Signal
Status Open Stop Reversing
Closed Opens* no effect no effect
Opening Stops Stops no effect
Opened Closes* no effect no effect
Closing Reverses* Stops Reverses*
Stopped Closes.
Opens if
reversing
device is
triggered*
no effect no effect
Logic E2
Gate Signal
Status Open Stop Reversing
Closed Opens* no effect no effect
Opening Stops Stops no effect
Opened Closes* no effect no effect
Closing Reverses* Stops Stops.
Reverses* when
reversing device
no longer
triggered.
Stopped Closes.
Opens* if
reversing
device is
triggered.
no effect no effect
Logic A1
(This logic mode makes the best use of
reversing devices.)
Gate Signal
Status Open Stop Reversing
Closed Opens and
then closes
after timed
pause
no effect no effect
Opening no effect Stops no effect
Opened Closes after
5 sec pause*
Pause count
is disabled
Pause count is
interrupted until
reversing device
is no longer
triggered*
Closing Reverses Stops Reverses
Stopped Closes.
Opens* if
reversing
device is
triggered.
no effect no effect
Logic A2
Gate Signal
Status Open Stop Reversing
Closed Opens and
then closes
after pause
time
no effect no effect
Opening no effect Stops no effect
Opened Closes
after 5 sec*
Pause count
is disabled
Pause count is
canceled. Closes
5 sec after
reversing device
is no longer
triggered.
Closing Reverses Stops Stops. Opens
when reversing
device is no
longer triggered.
Stopped Closes.
Opens* if
reversing
device is
triggered.
no effect no effect
* If preflashing is selected, gate movement is delayed for an additional 5 seconds.