4
Technical Data
The 760 Operator
Parameter 760 Standard 760 Longer Leaf
760 Extra Long
Leaf
Ambient temperature, deg F
(deg C)
-4 to 131 (-20 to 55)
Maximum duty cycle, cycles per
hour.
30
Thermal cut out, deg F (deg C) 212 (100)
Power voltage required, VAC* 115, ±10% or 230, +6 or -10%, 60 Hz* 230, +6 or –10%,
Absorbed power, W 220
Current drawn, A 230VAC= 1A, 115VAC= 1.5A 0.8A
Motor speed, rpm 1400 960
Type of oil Lubrication Engineers – MONOLEC 6105
Height (excluding spline) ×
width × depth, in. (cm)
6
1
/4 × 10
1
/4 × 19
1
/4
(15.9 × 26 × 49)
Weight, lb (kg) 28
1
/2 (13)
Oil quantity, qt (l) 1
1
/4 (1.2)
Hydraulic locking Opened and closed Not available Not available
Maximum gate weight, lb (kg) 1760 (800)
Maximum gate length, ft (m) 7 (2.1) 10 (3) 13 (4)
Maximum angle of rotation, deg 148 degrees
90-deg opening time, sec 12** 17**
Nominal torque, ft-lb (Nm) 399 (543) 200 (272)
* Your standard 220 VAC power source meets the specification for 230 VAC, +6 or -10%.
** Plus additional time for soft-stop versions
The Control Panel
The 760 Operator must be installed with a 450 MPS
control panel to be a U.L. recognized installation. The
450 MPS can be used to control a single 760 operator or
a dual (biparting) system. Both the control panel and
the operator must use the same power supply voltage.
The 450 MPS
To determine the voltage requirement of your 450 MPS
control panel, refer to the label on the transformer of the
control panel:
Label reads: 1450MPSUS = 220 VAC
1450MPSUS115 = 115 VAC
Operating logics available: E, EP, A, S, B, and C
(See pages 6, 7, & 8)