EasyManua.ls Logo

FAAC 760 - Installation; Setting Up the Gate

FAAC 760
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
A (Automatic) Logic
Gate
Status
Open A Open B Stop Opening
Reversing
Device(s)
Closing
Reversing
Device(s)
Warning
Light
Closed Opens both leaves
and closes them
after pause time
Opens single leaf
connected to
Motor 1 and
closes it after
pause time
No effect No effect No effect Off
Opening No effect No effect Stops Stops; gate closes
when reversing
device no longer
triggered
No effect On
Opened Interrupts the
pause time
Interrupts the
pause time
Stops No effect Gate remains open
until reversing
devices no longer
triggered
On
Closing Opens both leaves
immediately
Opens leaf
immediately
Stops No effect Depends on DIP
switch 4
Flashes
Stopped Closes the leaves Closes the leaf No effect
(opening is
inhibited)
No effect No effect (opening
is inhibited)
On
S (Security) Logic
Gate
Status
Open A Open B Stop Opening
Reversing
Device(s)
Closing
Reversing
Device(s)
Warning
Light
Closed Opens both leaves
and closes them
after pause time
Opens single leaf
connected to
Motor 1 and
closes it after
pause time
No effect No effect No effect Off
Opening Closes both leaves
immediately
Closes the leaf
immediately
Stops Stops; gate closes
when reversing
device no longer
triggered
No effect On
Opened Closes both leaves
immediately
Closes leaf
immediately
Stops No effect Gate remains open
until reversing
devices no longer
triggered
On
Closing Opens both leaves
immediately
Opens leaf
immediately
Stops No effect Depends on DIP
switch 4
Flashes
Stopped Closes the leaves Closes the leaf No effect
(opening is
inhibited)
No effect No effect (opening
is inhibited)
On
B (Manned, Pulsed) Logic
Gate
Status
Open A Open B Stop Opening
Reversing
Device(s)
Closing
Reversing
Device(s)
Warning
Light
Closed Opens 1 or both
leaves
No effect No effect No effect No effect Off
Opening No effect No effect Stops No effect Stops On
Opened No effect Closes 1 or both
leaves
No effect No effect No effect On
Closing No effect No effect Stops Stops No effect Flashes
Stopped Opens 1 or both
leaves
Closes 1 or both
leaves
No effect No effect No effect On

Other manuals for FAAC 760