7
ENGLISH
5 PROGRAMMING
It
is
necessary to access
PROGRAMMING
mode in order
to program
automated
system
operation
.
P
rogramming
is
divided in two parts: 1
st
LEVEL
and 2
nd
LEVEL
.
The status of the automated system
is
normally
shown
on the
display.
When push-
button
F is
pressed or when
F
and
+ are
pressed
simultaneously,
this gives access
to 1
st
or 2
nd
level programming.
To
restore the default settings, simply
re-
load the desired default
in
the
first
passage
of the 1
st
level programming.
The change of the programming
para
meters becomes effective,
while
final stor-
age
will
not take place
until
programming
mode
has
been exited and the
input
status
is
again displayed. If power supply to the
device
is
cut before going back to the
input
status
display, all the changes
made
will
be lost.
It
is
possible to return to the input status
display
and
store
all the parameters modi-
fied to that moment from any point of the
1
st
and 2
nd
level programming by pressing
keys F
and - simultaneously.
5.1 1
st
LEVEL
PROGRAMMING
T
o
access 1
st
level
programming,
press
push-button
F
.
When the board
is
turned on, the software
version
of the board as two figures sepa-
rated by a decimal point appears on the
LCD1 display.
If you
press key
F
again (and hold it down), the display
shows
the name of the
function
.
If you release the
key,
the display
shows
the value of the function that can be modified with
keys
+
and -.
If you
press
F
again (and hold it down), the display
shows
the name of the next function,
etc
.
When you reach the last function,
press
push-button
F
to exit the program and store the parameters.
The
display
shows
again the
status
of the
automated
system.
1
st
LEVEL
PROGRAMMING
Display
F
unction
Default
1
dF
DEF
AUL
T
:
1
Configures the parameters with
DEFAUL
T
values.
CU
If push-button
F
is
released, the value
CU
appears,
this
means that the standard
modified configuration has been selected by means of push-buttons and display. If
you
wish
to maintain
this
programming,
press
push-button
F
again,
otherwise press
+
and select default
1
.
1
LO
FUNCTION
L
OGICS:
E
Semiautomatic
.
EP
Semiautomatic Step”.
A
Automatic
.
A 1
Automatic1.
AP
Automatic Step”.
At Automatic with timer
function
.
S
Automatic Safety
devices
”.
SP
Automatic Safety Devices "Step”.
SA
Automatic with
reverse
during
pause
.
b
Semiautomatic
b”.
bC
Mixed
(
AP
pulse/ CH
dead-man).
C
Dead-man
.
E
PA
PAUSE TIME
A:
P
ause time with a
TOTAL
opening
command.
This
has effect only if the
automatic
logic was
selected. Adjustable from 0 to 59 secs. in one-second steps.
Subsequently, display changes to minutes and tens of seconds (separated by a point)
and
time
is
adjusted in 10-second steps, up to the maximum value of
9.5
minutes
.
E
.
g
. if the display
shows
2.5
, pause time
is
2 min. and 50 secs.
20
Pb
PAUSE TIME B:
P
ause time
with
a
PARTIAL
opening
command.
This
has effect only if the
automatic
logic was
selected. Adjustable from 0 to 59 secs. in one-second steps.
Subsequently, display changes to minutes and tens of seconds (separated by a point)
and
time
is
adjusted in 10-second steps, up to the maximum value of
9.5
minutes
.
E
.
g
. if the display
shows
2.5
, pause time
is
2 min. and 50 secs.
20