E045 17 732786 - Rev.C
ENGLISH
Display Basic Function Default
PA
PAUSE A and PAUSE B TIME (visualised only with Automatic logics)
Is the pause time in a TOTAL opening and PARTIAL opening (it is enabled only
if a logic with pause time has been selected).
Adjustable from 00 to 59 sec, in 1-second steps.
Next the value 59, the viewing changes to minutes and tenths of a second
(separated by a decimal point) and time is adjusted in 10-second steps up to
the maximum value of
9.5
minutes.
e.g.: if the display shows
2.5, the time is 2 min and 50 sec.
30
Mn
NR. OF MOTORS:
You can select the number of motors present in the system:
1 = 1 motor
2 = 2 motors
If the SETUP is performed with only one motor, and later two motors
are used, the board will signal error
14 - configuration error, which
can be deleted by repeating the SETUP with two motors or by re-
turning to one motor.
If a SETUP is performed with two motors and later only one is used,
the board will not signal an error. Only the motor connected to input
M1 will move.
2