E045 18 732786 - Rev.C
ENGLISH
Display Basic Function Default
F1
MOTOR 1 POWER:
You can adjust the maximum power of motor 1, which is the same during
both opening and closing.
01 = minimum power
50 = maximum power
If the power is modified, we recommend performing a new SETUP
- see the related paragraph.
If hydraulic motors are used, power must be programmed to maximum
level (
50).
25
F2
MOTOR 2 POWER (visualised only with the function Mn = 2):
You can adjust the maximum power of motor 2, which is the same during
both opening and closing.
01 = minimum power
50 = maximum power
If the power is modified, we recommend performing a new SETUP
- see the related paragraph.
If hydraulic motors are used, power must be programmed to maximum
level (
50).
25
En
ENCODER USE:
You can enable/disable the use of encoders:
Y = encoders on both motors
no = encoders disabled
no
Cd
DELAY FOR CLOSING LEAF (visualised only with the function Mn = 2):
Is the delay time for starting leaf 1 closing with respect to leaf 2. Makes it
possible to avoid overlapping of the two leaves.
Adjustable from
00 to 59 sec, in 1- second steps.
Next the value 59, the viewing changes to minutes and tenths of a second
(separated by a decimal point) and time is adjusted in 10-second steps up to
the maximum value of
1.3
minutes.
e.g.: if the display shows
1.2, the time is 1 min and 20 sec
05