E045S 10 532373 - Rev.A
Translation of the original instructions
ENGLISH
LED status Gate status
On Opening, Open, Pause
Off Closed
Flashing Closing
Alternatively, the output can be programmed to
indicate the automation closed status (programming
function Sp).
Do not exceed the maximum load of 100 mA.
ELECTRIC LOCK
J11
J9
J9
J11
F+/R1 -/R2
RADIO
2EASY
CONNECTIVITY
USB-A
MAIN
PE
N
L
230 V~
9 10 11 20 21
LAMP
M1 M2
M M
1PE N L 2 3 4 5 6 7 8
COM
OP
CL
COM
OP
CL
C C
230 V~
60 W max
24 V
"
3 W max
115V-F10A
230V-F5A
T0.8A
15 16 17 18
OP-A
OP-B
STOP
+24V
+24V
W.L.
LOCK
The E045S can control an electric lock mounted on the
leaf activated by motor 1 in order to lock the gate in
the closed position.
If the Bus 2easy encoder is installed and enabled, the
electric lock is activated only just before the leaf opens
from the closed position.
If the Bus 2easy is not enabled, the electric lock is ac-
tivated before each opening movement, irrespective
of the position of the leaf.
Use an FAAC 12 V~/24 V
"
electric lock or a generic 24
V
"
/0.5 A electric lock with a maximum current of 3 A.
XF RADIO MODULE
J5
The quick insertion connector J5 is specifically for FAAC
model XF radio modules.
Insert as shown in the figure.
To memorize radio control codes see § Accessories.
FLASHING LIGHT
J2
F+/R1 -/R2
RADIO
2EASY
CONNECTIVITY
USB-A
MAIN
PE
N
L
230 V~
9 10 11 20 21
LAMP
M1 M2
M M
1PE N L 2 3 4 5 6 7 8
COM
OP
CL
COM
OP
CL
C C
230 V~
60 W max
24 V
"
3 W max
115V-F10A
230V-F5A
T0.8A
15 16 17 18
OP-A
OP-B
STOP
+24V
+24V
W.L.
LOCK
The flashing light indicates that the gate is moving
and must be installed in a position that is visible from
both sides of the gate.
The flashing light must be a 230 V~, max 60 W model.
Pre-flashing of 3 s before movement can be enabled
via programming function PF.
MOTORS
J2
COM Motor COMMON contact
OP PHASE to open the electric motor
CL PHASE to close the electric motor
C Thrust capacitor
For single operator installations, connect the motor
to terminals M1.
For double operator installations, connect:
- the motor that opens first to terminals M1
- the motor that closes first to terminals M2
!
The operators MUST be connected to the earth of the
electrical system.