E045S 24 532373 - Rev.A
Translation of the original instructions
ENGLISH
10.1 FIRMWARE VERSION
The firmware version is show on the display for 5
seconds each time it is switched on.
10.2 CHECKING THE MOVEMENT
Access basic programming and use function M2 for
Leaf2 (displayed if the automation is configured for 2
leaves) and function
M1 for Leaf1.
1. The function displays
--.
2. Use buttons
++ and
--
in dead man mode. One of
the expected commands must be given:
++ to OPEN (oP on the display)
--
to CLOSE (cL on the display)
Otherwise, temporarily disconnect the power supply
and invert the phases (OP/CL) of the motor.
10.3 AUTOMATED SYSTEM STATUS
The display, other than in the programming menu,
provides information regarding the status of the
automation system:
8 Automated system status
00 CLOSED 06 CLOSING
01 OPEN 07 FAILSAFE IN PROGRESS
02 STATIONARY THEN OPENS 08 CHECK Bus 2easy
03 STATIONARY THEN CLOSES
09 PREFLASHING BEFORE OPEN-
ING
04 IN PAUSE
10 PREFLASHING BEFORE CLOS-
ING
05 OPENING
10.4 LEDS CHECK
9 bold indicates the condition of the LEDs with the
board powered, the gate at its halfway position and no
connected device active (=on ; =off).
9 Status of the LEDs
LED colour meaning
OPEN A red Total motion command active not active
OPEN B red Partial motion command active not active
STOP red Stop command not active active
5V blue Power supply 5 V on off
24V blue Accessories power supply 24 V
"
on off
BUS red Bus 2easy devices
see § Bus 2easy devices
BUS MON green Bus 2easy devices
USB red USB pen drive inserted (*) Installed not inserted
RADIO1 red Channel 2 Omnidec (*) active not active
RADIO2 red Channel 2 Omnidec (*) active not active
(*) Additional LED status or meanings are shown in the section on the accessory to which it refers.
LED colour meaning
ERROR red Error/alarm signalling alarm in progress error in progress not active
10. DIAGNOSTICS