Function default
M1
MOTOR 1 OPERATION in dead man mode
+ OPEN (displaying oP)
- CLOSE (displaying cL)
--
tL
SETUP
See the relative section.
--
St
LEAVING THE PROGRAMMING MODE
Y exit saving the settings
no exit without saving the settings
After having confirmed using button
FF, the display
indicates the STATUS of the automation:
Y
00 CLOSED 06 CLOSING
01 OPEN 07 FAILSAFE IN PROGRESS
02 STATIONARY THEN OPENS 08 CHECK Bus 2easy
03 STATIONARY THEN CLOSES
09 PREFLASHING BEFORE
OPENING
04 IN PAUSE
10 PREFLASHING BEFORE
CLOSING
05 OPENING
3 ADVANCED programming menu
Function default
rS
REVERSE STROKE ON OPENING AND SELECTABLE
CLOSE POWER
The reverse stroke assists the release of the
electric lock: it pushes against the closing stop
before opening.
Selectable close power assists the closing of the
electric lock.
DO NOT enable the function if there is not a me-
chanical closing stop fitted.
no disabled
Y enabled (3 s)
no
Od
LEAF OPENING DELAY (2 s)
(displayed only if
Mn = 2)
The delay is applied to MOTOR 2.
no disabled
Y enabled
Y
IP
REVERSE ON OBSTACLE
This function specifies the amount the leaf is
reversed after an obstacle has been detected.
no total reverse
Y partial reverse (2 s)
no
r1
SLOWDOWN LEAF 1
Specifies the deceleration space for the leaf con-
nected to MOTOR 1 (% of the total length of travel).
0099 (Adjustment step: 1%)
20
r2
SLOWDOWN LEAF 2
(NOT displayed if
Mn = 1)
Specifies the deceleration space for the leaf con-
nected to MOTOR 2 (% of the total length of travel).
0099 (Adjustment step: 1%)
20
PF
PRE-FLASHING
Enables/disables pre-flashing of 3 sec. before
each movement.
no disabled
Y enabled
no
EC
ANTI-CRUSHING SENSITIVITY
(displayed only if
En = Y)
This function species the speed with which the
anti-crushing system triggers after an obstacle
has been detected.
0010 (levels, 10 =maximum sensitivity)