10.5 ERRORS
An error is a condition that stops the automation.
When an error occurs: the ERROR LED turns on with
a steady light.
When not in the programming menus, press the
++ and
--
simultaneously to display the relative er-
ror code.
10.6 ALARMS
An alarm is a condition that does not affect the opera-
tion of the automation.
The ERROR LED flashes when an alarm occurs.
When not in the programming menus, press the
++ and
--
simultaneously to display the relative
alarm code.
10 Errors
01
Board failure Perform RESET. If the problem
persists, replace the E045S.
05
SETUP incorrect/
missing
Perform SETUP.
08
BUS 2easy de-
vice fault/con-
flict
Check the addresses of the devices.
09
BUS 2easy short
circuit/overload
Check the connections of the
BUS 2easy devices that are con-
nected and registered.
12
Call BUS 2easy Check the connections of the
BUS 2easy devices and repeat the
acquisition procedure if necessary.
13
FAIL SAFE
Test failed
FAIL-SAFE test of a device
failed. Check the connections,
programming, and that the pho-
tocell/sensitive edges are working
correctly.
14
Configuration
Error
Check the board configuration (basic
and advanced programming) and
if necessary carry out the SETUP
procedure.
17
Encoder 1 failure Make sure that the encoder is con-
nected properly. If the problem
persists, replace the encoder.
18
Encoder 2 failure Make sure that the encoder is con-
nected properly. If the problem
persists, replace the encoder.
19
Corrupted data
in memory
Repeat BUS 2easy programming
and registration.
11 Alarms
20
Obstacle de-
tected Leaf1
An obstacle that prevents the leaf
from moving has been detect-
ed. Remove the obstacle.
21
Obstacle de-
tected Leaf2
An obstacle that prevents the leaf
from moving has been detect-
ed. Remove the obstacle.
25
LOCK fault LOCK fault. Check the connec-
tion. Remove the cause of the
short circuit.
27
Consecutive ob-
stacles in open-
ing
The programmed number of con-
secutive obstacles in opening has
been reached. Remove the obsta-
cle. If the problem persists, repeat
the SETUP.
28
Consecutive ob-
stacles in closing
The programmed number of con-
secutive obstacles in closing has
been reached. Remove the obsta-
cle. If the problem persists, repeat
the SETUP.
30
Radio code
memory full
The radio memory is full.
Use an additional DECODER/XR2.
module if necessary.
31
Intrusion at-
tempt in pro-
gress
An attempt to open the leaf manu-
ally has been detected. Start a
movement.

Related product manuals