E045S 14 532373 - Rev.A
Translation of the original instructions
ENGLISH
Function default
rB
SEARCH FOR STOP
(displayed only if
En = Y)
This function specifies the angular space in which
to search for the opening/closing stop. In this
space, the automation is stopped by a mechanical
stop/obstacle and not by the anti-crushing system.
00 ~1°
02 ~4°
02
Sp
PROGRAMMING OUTPUT W.L.
00 LED function
06 automation closed warning
00
tA
ADDITIONAL OPERATING TIME
(displayed only if
En = no)
Adds additional operating time at the end of the
movement.
00…30 (Adjustment step: 1 s)
03
St
LEAVING THE PROGRAMMING MODE
Y exit saving the settings
no exit without saving the settings
After having confirmed using button
FF, the display
indicates the STATUS of the automation:
Y
00 CLOSED 06 CLOSING
01 OPEN 07 FAILSAFE IN PROGRESS
02 STATIONARY THEN OPENS 08 CHECK Bus 2easy
03 STATIONARY THEN CLOSES
09 PREFLASHING BEFORE
OPENING
04 IN PAUSE
10 PREFLASHING BEFORE
CLOSING
05 OPENING
6.3 OPERATING LOGICS
i
the STOP command has priority in all the logics and
stops the automation.
The CLOSE command always closes the automation.
■
E SEMI-AUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening, stops the gate and the next
OPEN command closes it.
OPEN during closing, causes it to reopen.
The triggering of the photocells: during movement,
reverses the gate.
■
EP SEMI-AUTOMATIC STEP-BY-STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening or closing, stops the gate and
the next OPEN command reverses the direction.
The triggering of the photocells: during movement,
reverses the gate.
■
SP AUTOMATIC STEP BY STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during pause, causes it to close.
OPEN during opening or closing, stops it and the
next OPEN command reverses the direction.
The triggering of the closing photocells: during
pause, closes the gate - during opening, requests
closing - during closing, causes the gate to open and
then closes it immediately.
■
A AUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during the pause, resets the pause time.
OPEN during opening, is ignored.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during pause,
reloads the pause time.