10
ENGLISH
Display Basic Function
cF
0124365
M2
MOTOR 2 dead-man DRIVE mode (visualised only with the function
Mn = 2)
+
OPENS (visualising
oP) until the button is held down
-
CLOSES
(visualising cL) until the button is held down
-- -- -- --
M1
MOTOR 1 dead-man DRIVE mode
+
OPENS (visualising
oP) until the button is held down
-
CLOSES
(visualising cL) until the button is held down
-- -- -- --
tL
WORK TIME LEARNING (SETUP):
See the related paragraph.
-- -- -- --
St
AUTOMATED SYSTEM STATUS:
You can exit programming, choosing whether or not to save the configuration you just performed.
1. set the choice:
Y to SAVE and EXIT the programming
no to EXIT the programming WITHOUT SAVING
2. press the button F to confirm; at the end the display returns to visualize the automated system status:
Y
00 = CLOSED
01 = OPEN
02 = Stationary then “OPENS”
03 = Stationary then “CLOSES”
04 = In “PAUSE”
05 = during Opening
06 = during Closing
07 = FAIL SAFE in progress
08 = checking BUS-2EASY devices in progress
09 = Pre-flash then “OPENS”
10 = Pre-flash then “CLOSES”
11 = Emergency open
12 = Emergency close
HP = Hold position
WARNING If power is lost to the board prior to confirmation (step 2.), all changes made will be
lost.
F
+
-
You can EXIT programming at any time: press and hold F and then also
-
to switch directly to St.