1
ENGLISH
CE DECLARATION OF CONFORMITY
Manufacturer: FAAC S.p.A.
Address: Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY
Declares that: The E124 control unit
conforms to the essential safety requirements of the following EEC directives
2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic Compatibility Directive
Additional note:
7KLVSURGXFWXQGHUZHQWWHVWVLQDW\SLFDOXQLIRUPFRQ¿JXUDWLRQ
(all products manufactured by FAAC S.p.A.).
Bologna, 01 March 2014
CEO
A.Marcellan
E124 control unit – rapid guide
Primary power feed from mains
with switching power feed 230/115 V~ - 50/60 Hz
Secondary power feed
24 V
- 16 A max. (min. 20 V
. - max. 28 V
.)
Power absorbed from mains
stand-by = 4W max. ~ 400 W
Max. load for motor
7 A
Power feed for accessories
24 V
Accessories max. current
24V
max. 500 mA, BUS-2EASY max. 500 mA
Battery charge current
180 mA
Operating ambient tempeature
(-20 - +55) °C
Protective fuses for unit
All self resetting
Protective fuses for power pack
2.5 A
Function logics Semiautomatic, Automatic, “step-by-step” Semiautomatic, Automatic with reverse during pause,
Automatic step-by-step, Safety devices automatic, Safety devices step-by-step automatic, “b”
Semiautomatic, mixed logic “bC”, Dead-man, Automatic with timer function
Work time
Programmable (from 0 to 9 min 50 sec)
Pause time
Programmable (from 0 to 9 min 50 sec)
Motor power
Programmable on 50 levels
Motor speed
Programmable on 10 levels
Connector inputs
Switching feeder, Battery, Decoder/Minidec/RP, X-COM, module XF433/868, USB
Terminal board inputs
BUS-2EASY, Inputs from IN1 to IN5, Travel limit device, Encoder.
Terminal board outputs
Flashing lamp, Motors, Electrical lock, OUT1, OUT2 (programmable), power feed to accessories
Programming
1st and 2nd lev. with 3 keys (+, -, F) and LCD display./ 3rd lev. with PC connected via USB
TECHNICAL SPECIFICATIONS
WARNINGS
- Important! For the safety of people, it is important that all the instructions be carefully observed.
- Incorrect installation or incorrect use of the product could cause serious harm to people.
- Carefully read the instructions before beginning to install the product and keep them for future reference.
- The symbol
indicates notes that are important for the safety of persons and for the good condition of the automated system.
- The symbol
draws your attention to the notes on the characteristics and operation of the product.
- Before attempting any work on the control unit (connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with adequate tripping threshold,
- Connect the earth cable to the relevant terminal.
- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any electrical
disturbance, use separate sheaths or a screened cable (with the screen earthed).
These instructions are to be considered as a rapid guide for installation. The complete instructions can be downloaded at
the following address: www.faacgroup.it
To access PROGRAMMING FROM PC/MAC, connect the USB cable to the dedicated connector and consult the relative
instructions.