7
ENGLISH
BASIC PROGRAMMING
Display Basic Function
cF
0124365
cF
0 Configures the parameters with DEFAULT values corresponding
to an installation with non-FAAC operators. (see column
cF 0).
1 Configures the parameters with DEFAULT values corresponding
to an installation with operators FAAC 412, 413/415, 770, 390,
770N (see column
cF 1).
2 Configures the parameters with DEFAULT values corresponding
to an installation with operators FAAC 391 (see column
cF 2).
3 Configures the parameters with DEFAULT values corresponding
to an installation with operators FAAC S700H/S800H (see column
cF 3).
4 Configures the parameters with DEFAULT values corresponding
to an installation with operators FAAC 418. (see column
cF 4).
5 Configures the parameters with DEFAULT values corresponding
to an installation with operators FAAC S450H (see column
cF
5).
6 Configures the parameters with DEFAULT values corresponding
to an installation with operators FAAC S800H ENC (see column
cF 6).
PC Mixed configuration from a PC/MAC
At the time of changing the set motor type on the board,
the relevant defaults are uploaded.
0124365
dF
DEFAULT:
Y indicates that all the set values correspond to the default values.
no indicates that one or more set values are different from the de-
fault
.
Set
Y if you want to restore the default settings.
YY YY
LO
FUNCTION LOGICS:
E Semi-automatic
EP Semi-automatic Step-by-Step
S Automatic Safety Devices
SA Automatic with reversal during pause
SP Automatic Step-by-Step Safety Devices
A1 Automatic 1
A Automatic
AP Automatic Step-by-Step
At Automatic timer
b Semi-automatic “b”
bC Mixed (Pulses for opening / Dead-man commands for closing)
C Dead-man
CU Logic modified from a PC/MAC
Other more detailed programming possibilities are feasible
by programming with a PC (see dedicated instructions).
EE EE