ENGLISH
Display Basic Function
cF
0124365
PA
PAUSE TIME A (visualised only if the selected logic allows
automatic reclosing):
Pause time following a TOTAL opening command. It has only effect if a
logic with pause time was selected. Can be adjusted from 0 to 59 sec.
in one-second steps.
Next, the viewing changes in minutes and ten seconds (separated by a
dot) and time is adjusted in 10-second steps, up to the maximum value
of
9.5 minutes.
E.g.: if the display shows
2.5, the pause time will be 2 min. and 50 sec.
30 30 30 30
Pb
PAUSE TIME B (visualised only if the selected logic allows automatic
reclosing):
Pause time following a PARTIAL opening command. It has only effect
if a logic with pause time was selected.
30 30 30 30
Mn
NR. OF MOTORS:
You can select the number of motors present in the system:
1 = 1 motor
2 = 2 motors
If the SETUP is performed with only one motor, and later
two motors are used, the board will signal error
14 - con-
figuration error, which can be deleted by repeating the
SETUP with two motors or by returning to one motor.
If a SETUP is performed with two motors and later only one
is used, the board will not signal an error. Only the motor
connected to input M1 will move.
When programming from a PC/MAC, you can select different
partial openings.
02 02 02 02
F1
MOTOR 1 POWER:
You can adjust the maximum power of motor 1, which is the same during
both opening and closing.
01 = minimum power
50 = maximum power
If the power is modified, we recommend performing a new
SETUP - see the related paragraph.
Other more detailed programming possibilities are feasible
by programming with a PC (see dedicated instructions).
25 25 40 35
F2
MOTOR 2 POWER (
visualised only with the function Mn = 2):
You can adjust the maximum power of motor 2, which is the same during
both opening and closing.
25 25 40 35
SP
SPEED:
Adjusts the motion speed of the motors. There are 10 levels. The value
is relative and not absolute, because the speed value refers to the
weight of the leaf measured during the SETUP cycle
01 = minimum speed
10 = maximum speed
Other more detailed programming possibilities are feasible
by programming with a PC (see dedicated instructions).
08 08 08 08