16
+
ENGLISH
In STAND BY (gate closed and in stand-by) with BUS-2EASY Encoder on leaf 1 and leaf 2 and
BUS-2EASY Photocells correctly connected and entered.
In case of BUS-2EASY Encoder on leaf1 and leaf 2 and BUS-2EASY Photocells correctly con-
nected and entered and with closing photocells engaged:
Encoder on leaf 1 cor-
rectly entered
Encoder on leaf 2 cor-
rectly entered
at least one pair of opening
photocells correctly entered
at least one pair of closing
photocells correctly entered
Fig. examples of BUS-2EASY status visualization on display.
CHECKING THE SECURING DEVICES ENTERED ON THE BOARD
To verify the types of BUS device recognised through the entry:
1. Press and hold the
+
button during stand-by visualisation; the segments corresponding to at least one entered device will go ON. E.g.:
To check the condition of the BUS-2EASY connection, verify the LED on the board:
LED DL15 (Red)
ON Safety device engaged or pulse generator active
OFF NO safety device engaged neither pulse generator active
LED DL14 (Green)
ON steady Normal activity (led ON even if there are no devices).
Slow blinking (blink every
2,5 sec)
BUS-2EASY line short-circuit.
Rapid blinking (blink every
0.5 sec)
Error in the
BUS-2EASY connection.
Repeat the device entry. If the error occurs again, check:
- That there are no more than one device in the system with the same address.
- Calling error (number > or < the connected BUS devices).
- FAIL SAFE error on the BUS device.
OFF Board in Sleep mode (if used).
TIME LEARNING - SETUP
When the board is powered, if a SETUP has never been performed, or if the board requests it, on the display S0 indicates that a SETUP must
be performed.
During SETUP, the connected BUS-2EASY accessories are always entered. The BUS-2EASY encoders entered by the SETUP
must always be enabled using the parameter
En (BASIC Programming).
If a system without an encoder is installed, mechanical stops will be required for the leaves.
During SETUP all safety devices are disabled! Therefore, carry out the operation avoiding any transit in the leaf movement
area.